| Technical indicators of spectrum analysis | 
| Frequency range | 30MHz ~ 6GHz | 
| Frequency stability | 10-7 | 
| Frequency accuracy | 10-7 | 
| Spectrum purity | Single side band phase noise | -100dBc@1kHz,1GHz  -103dBc@10kHz,1GHz -104dBc@100kHz,1GHz  -125dBc@1MHz,1GHz | 
| Signal processing | Instantaneous bandwidth | 100MHz | 
| RBW | 10Hz ~ 5MHz | 
| Maximum damaged input signal power (continuous wave) | 26 dBm shutdown prevention (reference level > 0 dBm) 10 dBm startup prevention (reference level < 0 dBm) | 
| Detection method | Normal, sampling, peak value, RMS | 
| Technical indicators of network analysis | 
| Frequency range | 30MHz ~ 6GHz | 
| Measurement | Measurement parameters | S11 (external bridge) S21 | 
| Display format of measured data | LogMag(dB), Phase(Deg), Group Delay, SWR,   Smith, Impedance | 
| Resolution bandwidth range | 100Hz ~ 1MHz | 
| Resolution bandwidth step | 100Hz | 
| Transmitter output level | -9dBm ~ -30dBm | 
| Transmitter output level step | 1dB | 
| Transmitter maximum RF input power | 26dBm | 
| Dynamic measurement range | 30MHz ~ 600MHz | Use the embedded calibration (Averaging function enabled, average factor 10) | >120dB | Do not use the embedded calibration (Averaging function enabled, average factor 10) | >90dB | 
| 600MHz ~ 4.5GHz | >105dB | >75dB | 
| 4.5GHz ~ 6GHz | >100dB | >70dB | 
| Amplitude accuracy | 30MHz ~ 4.5GHz | Averaging function enabled, average factor 10 | ±0.4° | Averaging function disabled | ±1° | 
| 4.5GHz ~ 6GHz | ±0.8° | ±3° | 
| Group delay aperture | 1 ~ 6001 | 
| Technical indicators of dual-channel vector signal generation | 
| Frequency range | 30MHz ~ 6GHz | 
| Frequency stability | 10-7 | 
| Frequency accuracy | 10-7 | 
| Spectrum purity | Harmonic suppression | -35dBc@1GHz (typical) | 
| Clutter suppression | -53dBc@1GHz (typical) | 
| Amplitude | Dynamic output signal power range | -120dBm~10dBm | 
| Output signal power step | 0.1dB | 
| Channel and coherence characteristics | Number of channels | Dual-channel coherence | 
| Dual-channel phase coherence characteristics | 2° | 
| Dual-channel amplitude coherence characteristics | 0.3dB | 
| Dual-channel coherence adjustment | Phase adjustment; amplitude adjustment; group delay adjustment | 
| Signal processing | Maximum signal bandwidth | 120MHz | 
| Resolution | 16 bit | 
| Arbitrary waveform storage depth | 1GSample@ single-channel 500MSample@ dual-channel | 
| External reference frequency range | 5MHz~100MHz | 
| Technical indicators of oscilloscope | 
| Number of channels | Independent four-channel | 
| Sample rate | 1GSample/s | 
| Signal bandwidth | 250MHz | 
| Storage depth | 64k | 
| Waveform calculation | +- X / FFT reverse direction | 
| Automatic measurement | Maximum value, minimum value, peak-to-peak value, period, frequency, rise time, fall time, positive duty cycle, negative duty cycle, positive pulse width, negative pulse width, etc. |